    TDSP-2800GI Split Pipe Wall-mounted Ultrasonic Flowmeter Application Field:Process control: food, pharmacy, chemical industry, electronics, water treatment, cold and hot water supply, oil supply pipeline, central air conditioning systemEnvironmental protection of resources: civil and industrial water supply, water conservancy and hydropower, agricultural irrigation, clean water and sewage treatment, sewage monitoringPetrochemical industry: crude oil production, crude oil transportation, refined oil transportation, oil terminal trade settlementTDSP-2800GI Split Pipe Wall-mounted Ultrasonic Flow...
  • 发布时间: 2019 - 01 - 15
    价格:
    0
    市场价:
    0
    会员价:
    ¥0
    TDSP-2800GJ Split Insert Wall-mounted Ultrasonic Flowmeter Application Field:Process control: food, pharmacy, chemical industry, electronics, water treatment, cold and hot water supply, oil supply pipeline, central air conditioning systemEnvironmental protection of resources: civil and industrial water supply, water conservancy and hydropower, agricultural irrigation, clean water and sewage treatment, sewage monitoringPetrochemical industry: crude oil production, crude oil transportation, refined oil transportation, oil terminal trade settlementTDSP-2800GJ Separately Inserted Wall-mounted Ultr...
  • 发布时间: 2019 - 01 - 15
    价格:
    0
    市场价:
    0
    会员价:
    ¥0
    1. Product introductionTDSP double-channel external clamp ultrasonic flowmeter is a double-channel ultrasonic flow measurement product adopting American technology. Each channel can achieve measurement accuracy. Double-channel redundancy greatly improves the accuracy and stability of the flowmeter, and overcomes the defect that mono-channel products are not suitable for flow field changes and have low accuracy and unstable flow.  The measurement principle is still based on the time delay method. Due to the optimized design of two channels, the influence of turbulence randomness on measure...
  • Overview
  • Specifications
  • Parameter

1. Product introduction


TDSP double-channel external clamp ultrasonic flowmeter is a double-channel ultrasonic flow measurement product adopting American technology. Each channel can achieve measurement accuracy. Double-channel redundancy greatly improves the accuracy and stability of the flowmeter, and overcomes the defect that mono-channel products are not suitable for flow field changes and have low accuracy and unstable flow.  The measurement principle is still based on the time delay method. Due to the optimized design of two channels, the influence of turbulence randomness on measurement is overcome to a great extent, and the adaptability and measurement accuracy to different working conditions are greatly improved, making small flow measurement more guaranteed.


In addition, the TDSP double-channel external clamp ultrasonic flowmeter uses advanced digital signal processing technology to make the dead angle of sensor design very small, and it is not easy to accumulate impurities such as rust and scale, thus solving the biggest hidden danger of interference of common ultrasonic flowmeter by impurities such as iron filings and welding slag, and being especially suitable for water quality with high impurity content.


TDSP double-channel external clamp ultrasonic flowmeter uses a high-speed DSP processor to make the response speed of the measurement system less than 0.1 second, which is more than 10 times faster than the common flowmeter. It can be used as a quantitative control measurement standard, especially suitable for flow measurement of high viscosity oil, chemical products and ultra-pure water. It can also be connected with two temperature sensors as calorimeters.  When more heat function is needed, GFM can also be used as the flow measurement part of calorimeter and connected to the calorimeter through 4-20mA as the flow measurement part.


1.2 Product Features


★ Flow measurement adopts double-channel ultrasonic technology to ensure measurement accuracy and stability;


★ Adopt high-speed DSP processor, with response speed reaching 0.1 second;


★ Advanced digital signal processing technology, the measurement is not interfered by iron filings, welding slag and other impurities;




★ Different sensors can be connected to solve the problem of multi-bubble application on site






1.3 Technical Indicators

 Technical indicators

Application

Measurable liquid

Most single-phase liquids. Less than 5% particles or bubbles.

Pipe material

Stainless steel, PVC, carbon steel.

Operating ambient temperature

-40℃~ +60℃

Measured fluid temperature

-20℃~ +120℃

Explosion-proof grade

Flameproof ExidII BT4


Intrinsically safe exiaibt4


Dangerous areas of body and dust


Performance index

Velocity range

Nominal accuracy flow rate range 0.1 ~ 12.5 m/s

measurement accuracy

±0.5%

Sensitivity

0.001m/s.

Measurement repeatability

±0.2%

Electronic box

the protection grades

IP65

Power supply

12~24V DC, 0.5A.

Electrical interface

Waterproof head

2×M20×1.5 

LCD display

128*64 dot matrix liquid crystal

Keyboard input

4 keys

Input and output signal

Serial communication

RS485, MODBUS RTU 

Flow output

Self-powered 4-20mA output or 0-24V pulse output

 


Scan WeChat QR Code
Scan two-dimensional code of mobile phone
Customer service email kelandi@163.com
400-888-9999 全国免费24小时客服热线
Address: C1-902, Innovation Building, 182 Science Avenue, Guangzhou Science City | TEL:020-82029606 | E-mail:290268806
Copyright ©2019 - 2020 Guangzhou fangshi instrument co., ltd.
犀牛云提供企业云服务
X
3

SKYPE 设置

4

阿里旺旺设置

等待加载动态数据...

等待加载动态数据...

5

电话号码管理

  • 18988841997
6

二维码管理

等待加载动态数据...

等待加载动态数据...

展开